Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. pharm. sci ; 50(3): 611-619, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-728687

ABSTRACT

Here, a spectrofluorimetric method for the determination of potassium losartan (PL) in pharmaceutical products is described. The effects of critical parameters, pH, acid molarity, and temperature, on the fluorescence intensity of PL were analyzed, and these parameters were optimized using a central composite design (CCD). The highest fluorescent intensity at excitation (λex) and emission (λem) wavelengths of 248 nm and 410 nm, respectively, was achieved using 0.01 M sulfurous acid (pH 2) at 21.6 °C. Under optimum conditions, the method was linear from 0.025-0.5 µg/mL, with a reasonably high correlation coefficient (0.9993). Furthermore, the method was very sensitive (LOQ, 0.006), accurate (RE, ≤7.06), and precise (%RSD, ≤6.51). After development and validation of the method, samples containing PL were analyzed with this method, and the obtained data were statistically compared with those obtained with a previously published reference method using a two one-sided equivalence test (TOST). According to the data, the results from the proposed and reference assays were equivalent.


Descreve-se método espectrofluorométrico para a determinação de losartana potássica (PL) em produtos farmacêuticos. Os efeitos de parâmetros críticos (pH, molaridade ácida e temperatura) na intensidade da fluorecência foram otimizados usando o planejamento de componente central (DCC). A mais alta intensidade fluorescente com λex=248 nm e λem= 410 nm foi obtida usando ácido sulfúrico 0.01 M (pH 2) e 21.6 ºC. Nas condições ideais, a linearidade do método foi estabelecida na faixa de concentração de 0.025-0.5 µg/mL com coeficiente de correlação bastante elevado (0.9993). Além disso, o método foi muito sensível com valor de LOQ 0.006, exato (RE≤7.06) e preciso (RSD%≤6.51). Depois do desenvolvimento e validação do método, amostras de medicamentos contendo PL foram analisadas com este método e os resultados obtidos foram comparados estatisticamente com método de referência, publicado anteriormente, usando o Teste de equivalência TOST (Teste de Equivalência Unilateral). De acordo com os dados estatísticos, os resultados do ensaio de referência e do método proposto foram equivalentes.


Subject(s)
Spectrometry, Fluorescence/methods , Chemistry, Pharmaceutical/methods , Losartan/classification , Composite Resins
2.
Braz. j. pharm. sci ; 50(3): 629-638, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-728700

ABSTRACT

A viable cost-effective and isocratic approach employing C-18 column (250 mm × 4.6 mm, 5 µm) based HPLC has been utilized to separate and estimate the drugs, rosuvastatin, amlodipine and their stress induced degradation products, simultaneously in pharmaceutical formulations. Focused on ICH guideline parameters, the efficient separation of both drugs and their degradation products was achieved by optimizing a 30:70 (v/v) solvent mixture of acetonitrile and 0.1 M ammonium acetate buffer (pH 5) as mobile phase. The flow rate of the mobile phase was 1.5 mL/min and all the detections were carried out at 240 nm using UV detector. The method was linear in the concentration range of 1-200 µg/mL for rosuvastatin with 0.996 coefficient of determination value. For amlodipine, linearity was in the range of 0.5-100 µg/ml with 0.994 coefficient of determination value. Both the drugs along with their degradation products were separated in less than twenty minutes. The results of within-day and between-day precision were varied from 0.72 to 1.81% for rosuvastatin and 0.83 to 1.88% for amlodipine. The results show that this ICH validated method can be employed successfully for the routine as well as stability quantification of both the active ingredients simultaneously in pharmaceutical formulations.


Utilizou-se abordagem de viabilidade custo-efetividade e isocrática, baseada em CLAE, empregando coluna C-18 (250 mm x 4,6 mm, 5 µm) para separar e avaliar os fármacos, rosuvastatina, anlodipino e seus produtos de degradação induzida por estresse, simultaneamente, em formulações farmacêuticas. Focada nos parâmetros das diretrizes da ICH, a separação eficiente de ambos os fármacos e de seus produtos de degradação foi obtida por meio da otimização da fase móvel com mistura de solventes 30:70 (v/v), respectivamente, acetonitrila e tampão acetato de amônio O,1 M (pH 5). A velocidade de fluxo da fase móvel foi de 1,5 mL/min e todas as detecções foram realizadas em 240 nm, utilizando detector de UV. O método foi linear no intervalo de concentração de 1-200 µg/mL para a rosuvastatina com coeficiente de determinação 0,996. Para o anlodipino, a linearidade ficou na faixa de 0.5-100 µg/mL, com coeficiente de determinação 0,994. Ambos os fármacos, junto com seus produtos de degradação, foram separados em menos de vinte minutos. Os resultados de precisão intra-dia e inter-dia variaram de 0,72 a 1,81% para a rosuvastatina e de 0,83 a 1,88%, para o anlodipino. Os resultados mostram que este método validado pelo ICH pode ser empregado com sucesso tanto para a rotina quanto para a quantificação simultânea da estabilidade de ambos os ingredientes ativos em formulações farmacêuticas.


Subject(s)
Chemistry, Pharmaceutical/classification , Chromatography, High Pressure Liquid/methods , Amlodipine/analysis , Rosuvastatin Calcium/analysis , Acetonitriles/analysis
SELECTION OF CITATIONS
SEARCH DETAIL